The 3 splitters in the photo are from left to right; Splitter, RJ45 Injector, and Injector (discontinued).
All 3 splitter types have 3 data ports. 1 input from the generator and then 2 side by side ports for GenMon (right side) and optionally a compatible MobileLinks on the left side.
The purpose of each port is NOT interchangeable, using the splitters in a way other than directed will at best just not work, but could cause damage to any or all of the connected devices.
On the "top" of each is the generator port. This is labeled "Generator" and is on an edge with no other data ports.
On the "bottom" of each is a Molex MobileLink port on the left. On right is the GenMon port, this is a Molex on the Splitter and Injector, and an RJ45 port on the RJ45 Splitter.
THIS IS NOT A NETWORK PORT. We use RJ-45, with the Ethernet standard, as a Molex cable extender. Ethernet cables are readily available, cheap, and well understood by many handymen, electricans, and low voltage professionals making it a cabling option that requires no additional knowledge. Do not plug it into network equipment. It will not work and might cause damage to connected devices.
MobileLink units come in 2 flavors, one with RS-232 connection and one with a RS-485 connection. The RS-232 units are not compatible with GenMon and you have to use one or the other, the RS-485 units can be used at the same time as GenMon. If you look at the plug, consider how it plugs into the splitter. If on the top row the 2 left pins are populated, then it is a RS-232 (not compatible). If on the top row the 2 right pins are populated it is a RS-485 MobileLink (compatible). If you are not sure, contact us with a photo via the contact page on our store, Facebook messenger, or if you have ordered from us you can reply to the order email.
Our RJ-45 splitter is 2 parts. First is the injector, this is setup the same as the splitter but with a RJ-45 plug instead of Molex for the GenMon connection. This part is also included with our USB RJ-45 product and our USB Kits when RJ-45 is selected. The second part is an ejector, this has RJ-45 input and Molex output. This allows connecting a HAT or pHAT at a significant distance from the generator. Power the Pi or other accessories this way is not supported, only data connectivity is supported.
Our injector is now discontinued, however we are maintaining documentation for it.
The injector starts as a splitter and adds 2 features, a barrel plug and a cutoff switch labeled "GENPWR".
The barrel plug is for a 5.5x2.5mm power cable that supplies 12v, center positive preferred but there is reverse polarity protection.
The GENPWR switch connects/disconnects the 12v feed from the controller over the Molex cable, 12v is only present on the Evolution 2 controller. When a power cord is plugged into the injector, GENPWR should be in the OFF position which disconnects the 12v line from the controller so it can be replaced with 12v from the battery. If yours is equipped with a red switch, the 1 indictor means OFF.
FAILURE TO CONNECT THIS PROPERLY CAN DESTROY YOUR CONTROLLER.
Our v1 and v2 HATs and pHATs support being powered over the Molex port. That has been removed in v3 to improve safety and reduce the possibility of someone not following instructions and damaging their equipment.